Test sandy, loam, silt-loam, and clay infiltration rates against pit depth so your drywell never gets rejected for slow >72-hour drainage.
Instant self-serve download + 30-Day Magic Edit Link (change address or numbers anytime free).
| Ln | Description & Prescriptive Formula | Code Ref | Input | Calculated |
|---|
Below is a complete step-by-step mathematical schedule generated from standard nameplate ratings so municipal plan examiners, homeowners, and contractors can verify every code formula:
| Line | Step Description & Formula | Code Reference | Rating | Calculated |
|---|---|---|---|---|
| 1 | Impervious Lot Coverage Ratio: (Existing - Removed + New Γ 1.00 Credit) / Lot Area (PASS) | Zoning β€ 35.0% | 9000 sf Lot Β· 400 sf New | 31.1% |
| 2 | Required Design Storm Capture Volume (Gross New Impervious Area Β· Direct Surface Capture) | V = A Γ (P/12) Γ C | 1.50 in (C=1.00) | 374 gal (50.0 ftΒ³) |
| 3 | Crushed Washed Angular Stone Infiltration Trench (AASHTO #57 Β· 40% Void Ratio Β· 10.0' L Γ 5.0' W Γ 2.5' D) | AASHTO #57 Trench | 10.0' L Γ 5.0' W Γ 2.5' D | 374 gal (50.0 ftΒ³) |
| 4 | Construction Material Take-Off: Clean Washed Stone (+5% waste) & 4 oz Non-Woven Geotextile (+15% overlap) | Field Take-Off | 125.0 ftΒ³ Stone | 6.81 tons Β· 201 sf Fabric |
| 5 | Soil Infiltration Drawdown Time at 0.25 in/hr (6 mm/hr) β Must Drain Within β€ 72.0 Hours (PASS) | EPA / MS4 β€ 72h | 0.25 in/hr | 48.0 hrs |
| 6 | Clearances Check (Foundation 15.0' β₯ 15' Β· Lot Line 10.0' β₯ 10' Β· Water Table 3.0' β₯ 2') & Net Detention | COMPLIANT | Setbacks OK | 374 gal (50.0 ftΒ³) |
Drawdown time depends purely on vertical effective water depth divided by soil infiltration rateu2014not pit length! Reducing stone depth from 4.5 ft to 2.5 ft while widening/lengthening the trench cuts emptying time by 44%.